CALYS 80 IS is an ATEX documenting multifunction calibrator within CALYS IS range. It is the perfect tool for advanced process maintenance and use on test bench in hazardous and non-hazardous areas. Suitable for all field and lab measurements, it can simultaneously measure and generate over two isolated channels various signals of temperature, resistance, process, pressure and frequency in one single instrument.
Providing extended functionalities (temperature simulation, scaling, steps, synthesizer, statistical functions…) and audit trails, CALYS IS series complies with both 21 CFR Part 11 and NADCAP Heat Treatment standards and makes advanced data exploitation and full data traceability easier. CALYS IS can store and recall up to 10 complete instrument configurations and values with manual or automatic recall for easy and quick work in the field.
The dual channel display allows a simultaneous indication of the measured and the simulated values. The graphic mode allows the trend to be displayed.
Specifications and performances in temperature @23°C ±5°C
Uncertainty is given in % of reading (CALYS 80 IS display) + fixed value.
Resistive probes: Measurement and simulation
Sensor | Range (Input and Output) | Resolution | Accuracy / 1 year |
Pt100 (= 3850) | -200°C to +850°C | 0.01°C | 0.01% RDG + 0.05°C |
Pt100 (= 3926) | -200°C to +850°C | 0.01°C | 0.01% RDG + 0.05°C |
Pt100 (= 3902) | -200°C to +650°C | 0.01°C | 0.01% RDG + 0.05°C |
Pt100 (= JIS SAMA) | -200°C to +600°C | 0.01°C | 0.01% RDG + 0.05°C |
Pt200 (= 3851) | -200°C to +850°C | 0.1°C | 0.01% RDG + 0.15°C |
Pt500 (= 3851) | -200°C to +850°C | 0.1°C | 0.01% RDG + 0.1°C |
Pt1000 (= 3851) | -200°C to +850°C | 0.01°C | 0.01% RDG + 0.1°C |
Cu10 (= 427) | -70°C to +150°C | 0.1°C | 0.01% RDG + 0.4°C |
Cu100 (= 428) | -180°C to +150°C | 0.1°C | 0.01% RDG + 0.05°C |
Ni100 (= 618) | -60°C to +180°C | 0.1°C | 0.01% RDG + 0.05°C |
Ni120 (= 672) | 0°C to +150°C | 0.1°C | 0.01% RDG + 0.05°C |
Connections: 2, 3 and 4 wires
Rtd simulation excitation current: from 0.1 to 4 mA without incremental error
Rtd measurement excitation current: 0.2 mA
Rtd cable compensation: up to 100 m (for each wire)
Rtd cable compensation error (Pt100): ± 0.005°C/ of total wire
Maximum load resistance: 600 Ω @ 20 mA
Thermocouples: Measurement and simulation
Type | Range | Résolution | Accuracy / 1 an |
J | -210 to +1200°C | 0.01°C | 0.01% RDG + 0.1°C |
K | -270 to +1370°C | 0.01°C | 0.01% RDG + 0.1°C |
T | -270 to +400°C | 0.01°C | 0.01% RDG + 0.1°C |
R | -50 to 1760°C | 0.1°C | 0.01% RDG + 0.2°C |
S | -50 to 1760°C | 0.1°C | 0.01% RDG + 0.2°C |
B | +50 à +1820°C | 0.1°C | 0.01% RDG + 0.3°C |
C | 0 to 2300°C | 0.1°C | 0.01% RDG + 0.2°C |
G | 0 to 2300°C | 0.1°C | 0.01% RDG + 0.3°C |
D | 0 to 2300°C | 0.1°C | 0.01% RDG + 0.3°C |
U | -200 to +400°C | 0.01°C | 0.01% RDG + 0.1°C |
L | -200 to +760°C | 0.01°C | 0.01% RDG + 0.1°C |
N | -270 to +1300°C | 0.01°C | 0.01% RDG + 0.1°C |
E | -270 to +1300°C | 0.1°C | 0.01% RDG + 0.1°C |
F | 0 to +1400°C | 0.1°C | 0.01% RDG + 0.1°C |
Display units: °C, °F et K
Resolution: 0.01°C / 0.01°F
Temperature scale: ITS90 and IPTS68
Reference junction compensation: internal automatic from -10°C to +55°C or external
Rj compensation drift: ± 0.002°C/°C (from -10 °C to +45 °C) – Class A Pt100
Input impedance: > 10 MΩ
Comments are closed.