AOIP-ATEX field documenting calibrator with high accuracy 0.01% (Model:CALYS 80 IS)

9
579
Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. ​​Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.

 CALYS 80 IS is an ATEX documenting multifunction calibrator within CALYS IS range. It is the perfect tool for advanced process maintenance and use on test bench in hazardous and non-hazardous areas. Suitable for all field and lab measurements, it can simultaneously measure and generate over two isolated channels various signals of temperature, resistance, process, pressure and frequency in one single instrument.

Providing extended functionalities (temperature simulation, scaling, steps, synthesizer, statistical functions…) and audit trails, CALYS IS series complies with both 21 CFR Part 11 and NADCAP Heat Treatment standards and makes advanced data exploitation and full data traceability easier. CALYS IS can store and recall up to 10 complete instrument configurations and values with manual or automatic recall for easy and quick work in the field.

The dual channel display allows a simultaneous indication of the measured and the simulated values. The graphic mode allows the trend to be displayed.

Specifications and performances in temperature @23°C ±5°C

Uncertainty is given in % of reading (CALYS 80 IS display) + fixed value.

Resistive probes: Measurement and simulation

Sensor Range (Input and Output) Resolution Accuracy / 1 year
Pt100 (= 3850) -200°C to +850°C 0.01°C 0.01% RDG + 0.05°C
Pt100 (= 3926) -200°C to +850°C 0.01°C 0.01% RDG + 0.05°C
Pt100 (= 3902) -200°C to +650°C 0.01°C 0.01% RDG + 0.05°C
Pt100 (= JIS SAMA) -200°C to +600°C 0.01°C 0.01% RDG + 0.05°C
Pt200 (= 3851) -200°C to +850°C 0.1°C 0.01% RDG + 0.15°C
Pt500 (= 3851) -200°C to +850°C 0.1°C 0.01% RDG + 0.1°C
Pt1000 (= 3851) -200°C to +850°C 0.01°C 0.01% RDG + 0.1°C
Cu10 (= 427) -70°C to +150°C 0.1°C 0.01% RDG + 0.4°C
Cu100 (= 428) -180°C to +150°C 0.1°C 0.01% RDG + 0.05°C
Ni100 (= 618) -60°C to +180°C 0.1°C 0.01% RDG + 0.05°C
Ni120 (= 672) 0°C to +150°C 0.1°C 0.01% RDG + 0.05°C

Connections: 2, 3 and 4 wires
Rtd simulation excitation current: from 0.1 to 4 mA without incremental error
Rtd measurement excitation current: 0.2 mA
Rtd cable compensation: up to 100 m (for each wire)
Rtd cable compensation error (Pt100):  ± 0.005°C/ of total wire
Maximum load resistance: 600 Ω @ 20 mA

Thermocouples: Measurement and simulation

Type Range Résolution Accuracy / 1 an
J -210 to +1200°C 0.01°C 0.01% RDG + 0.1°C
K -270 to +1370°C 0.01°C 0.01% RDG + 0.1°C
T -270 to +400°C 0.01°C 0.01% RDG + 0.1°C
R -50 to 1760°C 0.1°C 0.01% RDG + 0.2°C
S -50 to 1760°C 0.1°C 0.01% RDG + 0.2°C
B +50 à +1820°C 0.1°C 0.01% RDG + 0.3°C
C 0 to 2300°C 0.1°C 0.01% RDG + 0.2°C
G 0 to 2300°C 0.1°C 0.01% RDG + 0.3°C
D 0 to 2300°C 0.1°C 0.01% RDG + 0.3°C
U -200 to +400°C 0.01°C 0.01% RDG + 0.1°C
L -200 to +760°C 0.01°C 0.01% RDG + 0.1°C
N -270 to +1300°C 0.01°C 0.01% RDG + 0.1°C
E -270 to +1300°C 0.1°C 0.01% RDG + 0.1°C
F 0 to +1400°C 0.1°C 0.01% RDG + 0.1°C

Display units: °C, °F et K 
Resolution: 0.01°C / 0.01°F
Temperature scale: ITS90 and IPTS68
Reference junction compensation: internal automatic from -10°C to +55°C or external
Rj compensation drift: ± 0.002°C/°C (from -10 °C to +45 °C) – Class A Pt100
Input impedance: > 10 MΩ

Resource & Download

Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | 086 9421303 | 02873000184 | AOIP-ATEX field documenting calibrator with high accuracy 0.01% (Model:CALYS 80 IS).

Comments are closed.