Chandler Engineering-Dew Point Tester (Model:Chanscope II)

0
557
Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. ​​Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.

 ACCURATE DETERMINATION OF THE DEW POINT OF NATURAL GAS 

The Need

Natural gas pipeline operations are dramatically impacted by the presence or formation of liquids within the gas pipeline. The dew point of the natural gas must be periodically checked in order to ensure that troublesome liquid formation is not occuring in the pipeline. 

Operators and technicians using the standard Bureau of Mines Dew Point Tester to determine the dew point of the natural gas found it difficult to use. The mirror was difficult to view in good daylight; at night it was nearly impossible. The standard tester also required the user to take his sight off the mirror in order to determine the current mirror temperature and its rate of decrease. 

An easier to use manual dew point tester was needed. 

The Solution

AMETEK's Chandler EngineeringTM Chanscope IITM was designed to meet the need for a user friendly dew point tester. The Chanscope II measures the dew point of the sample gas through the use of a chilled mirror as required by ASTM D1142. 

Through a direct effort to make the device easier to use, Chandler Engineering developed the Chanscope II. The Chanscope II bears a number of significant improvements to useability over the standard dew point tester. 

  • The mirror is illuminated making it much easier to see dew formation and identify the type of dew on the mirror.
  • The temperature of the mirror is displayed above the mirror itself electronically thereby making it much easier to identify the exact temperature at which the dew forms.
  • The temperature sensor operates over the full range of possible dew points thereby eliminating the need to have multiple testers of varying dew point range.
Specifications
Accuracy: ±0.1°C (0.2°F) down to 0°C (32°F) 
±0.5°C (1.0°F) down to -100°C (-148°F) 
±1.0°C (2.0°F) down to -200°C (-328°F)
Dew Point Temperature Range: -200°C (-148°F) to ambient
Operating Pressure: Up to 5000 psig (34.6 MPa)
Connections: Sample inlet and outlet: 1/8” NPT; Refrigerant, 1/8” tube
Power: Battery-powered with 115VAC or 230VAC charger.
Ship Weight: 25 lb (11 kg)
Carrying Case: 14” x 18” x 7” (35.5cm x 20cm x 17.8cm)

Resource & Download

Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | 086 9421303 | 02873000184 | Chandler Engineering-Dew Point Tester (Model:Chanscope II).