Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.
The ADTS 405 is the latest in a series of reliable, high accuracy, air data test systems. The rugged, compact design has evolved as a result of GE Druck’s continuous research and development, customer feedback and experience gained from manufacturing thousands of automatic pressure controllers. This has enabled performance, maintainability, and operational simplicity to be optimised.
The ADTS 405 is a twin-channel Ps and Pt pressure control system used for the precision calibration/verification of aircraft pitot statics, compliant with RVSM (Reduced Vertical Separation Minima) requirements.
Features
- High accuracy, RVSM compliant
- Flightline and rack mount versions
- Civil and military specifications
- Integral or remote pressure/vacuum supplies
- Fully programmable for aircraft type
- Protection for aircraft instruments
|
Applications
The ADTS 405 is a twin-channel Ps and Pt pressure control system used for the precision calibration/verification of aircraft pitot statics, compliant with RVSM (Reduced Vertical Separation Minima) requirements.
|
Specifications
Rackmounted ADTS 405
The ADTS 405 is a 50 cm (19 in) rack mounting module housing the main control system with local front panel display and keypad. The remote hand terminal is optional for this model and a matched separate pressure/vacuum supply unit is available—please refer to PV 103R Datasheet.
Scaling Factors |
Altitude: ft metres Airspeed: knots, km/hr, mph Others: mbar, inHg, inH20 (4°C, 20°C, 60°F), mm Hg, kPa, hPa, psi. Airspeed: CAS (calibrated) : TAS (true—ability to enter temperature) |
Rate Control/Indication |
RoC: Rate of Climb Rt Ps Rate of Static Rt Pt: Rate of Pitot Rt Qc Rate of Pt-Ps Rt CAS: Rate of calibrated airspeed Rt EPR: Rate of engine pressure ratio |
Overpressure |
Negligible calibration change with up to 1.25 x FS overload applied. |
Calibration Stability |
Better than 50 ppm per year |
Recalibration |
Simple keypad instruction. 12 month interval suggested. Use of primary standard pressure reference is recommended (e.g. Ruska Model 2465 deadweight tester). |
Display |
LCD backlit, supertwist/wide angle viewing. 123 mm x 42 mm (4.8 in x 1.6 in) window with 4 lines of 20 characters 8 mm (0.3 in) high. Optional hand terminal display window 73 mm x 24 mm (2.87 in x 0.95 in) |
Response |
Two readings per second display value update. Five readings per second interface and control system updates. |
Power Supplies |
90 to 260 VAC at 47 to 440 Hz, 100 VA normal, 400 VA maximum |
Power Failure Protection |
In the event of a power interruption, the output ports will be vented to ambient conditions safely. On power reconnect, the system is in measure mode. |
Self Test |
Integral test routines and reporting for both electrical and pneumatic systems. |
Digital Interfaces |
Parallel printer interface available as standard. IEEE488.2 optional—earlier versions also available. |
Temperature Range |
Calibrated: 5°C to 35°C (41°F to 95°F) Operating: -10°C to 50°C (14°F to 122°F) Storage: -20°C to 70°C (-4°F to 158°F) |
Sealing |
ADTS 405 front panel is rainproof. |
Humidity |
0 to 90% condensing. “Tropicalised” pcb’s to MIL-T-28800 |
Shock/Vibration |
MIL-T-28800 Class 2. |
Safety Performance |
EN50081-1 for EMC emissions EN50082-1 for EMC immunity EN61010 for electrical and mechanical safety |
Physical |
13 kg (29 lb) nominal. Case dimensions: 485 mm x 270 mm x 305 mm (19 in x 10.5 in x 12 in) |
Pneumatic Connections |
Front panel mounted fittings with blanking caps Static: AN-6 37° flare Pitot: AN-4 37° flare
Fitted with replaceable filters Vacuum (AN6) and pressure (AN4) supply fittings on rear panel with 2.5 m (8 ft) long mating hoses. |
Pneumatic Supplies |
For normal use, dry air with source pressure at a maximum 25% above specified pressure range. Compatibility with other dry, non-corrosive gases can be provided. Please refer to GE. |
Flight line ADTS 405F
Transportable military cased version incorporating the ADTS 405 with built-in pressure/vacuum supplies. Control is via local keypad/display or standard remote control terminal.
Power Supply |
90 to 260 VAC at 47 to 440 Hz, 500 VA. 28 VDC option available. |
Digital Interfaces |
Standard parallel printer connection accessible via front panel protection cover. IEEE488 optional. |
Sealing |
Weatherproof in operating mode (lid removed). |
Electro Magnetic Compatibility |
To MIL-STD-461D |
Physical |
35 kg (77 lb) 762 mm x 320 mm x 480 mm (30 in x 13 in x 19 in) nominal. Wheels supplied for ease of transport. |
Pressure/Vacuum Unit |
Integral pneumatic supplies (PV 103F). Auxiliary connections for external supplies to boost or drive other equipment. Supply for vacuum hold down static adaptors also provided. |
Cart Mounted ADTS 405C
Towable, chassis mounted package incorporating the ADTS 405 with pressure/vacuum supplies and ability to include a Line Switching Unit (LSU) for multiple Ps and Pt outlets. For LSU please refer to separate Product Note. Control is via cart mounted display or standard remote hand terminal.
Power Supply |
As ADTS 405F with 10 m (33 ft) AC power lead. |
Sealing |
Weatherproof with all doors closed. |
Physical |
Weight: 250 kg (550 lb) Size (h x l x w): 1150 mm x 1350 mm x 700 mm (45 in x 53 in x 27 in) nominal. |
Towing |
Maximum safe speed 15 km/h (10 mph). Foam filled wheels 381 mm (15 in) diameter and a steering wheel 254 mm (10 in) diameter, nominal. |
Options
ADTS 405 Remote Control Terminal |
A handheld remote control facility for the rack mount ADTS 405 (standard with ADTS 405F/ADTS 405C). Complete with 2 m (6 ft) long cable. |
Lid Mounted Switching Manifold |
Two five-way manifolds for multiple output Ps and Pt ports. Each line has an individual manual shut-off valve. |
28 VDC Operation |
In addition to AC supply, a second power connector enables 28 VDC input for rack, flightline or cart versions. |
ADTS 405 Bench Case |
A case to enclose the ADTS 405 482.6 mm (19 in) rack unit for benchtop use. |
IEEE488 Interface (SCPI version) |
Current ADTS communications protocol. |
IEEE488 Interface (1975 version) |
Compatible with earlier ADTS units. |
IEEE488 Interface (SCPI & 1975) |
Both (E1) and (E2) provided for user choice. |
ADTS 405 Rear Ps/Pt Connections |
Duplicate connections provided at the rear in addition to front panel. |
Test Program Manager |
A software package with serial interface mode adaptor. Permits laptop PC based control. |
Altimeter Encoder Interface |
For altimeters with ICAO reporting encoders. Permits display of the bit stream and reporting of altitude value. |
ARINC 429 Interface |
Permits the ADTS to monitor data from an aircraft bus, display the 12 pitot static label information and transmit to the aircraft. |
Accessories |
AC power lead—2 m length (6 ft) approximately. Ps, Pt, pressure and vacuum hoses—2.5 m lengths (8 ft) approximately. Operators manual and calibration certificate also supplied as standard. |
Calibration Standards |
Instruments manufactured by GE are calibrated against precision calibration equipment traceable to international standards. |
|
Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó.
Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | 086 9421303 | 02873000184 | DRUCK-Air Data Test System( Model: ADTS 405).
Comments are closed.