Flowline-EchoSafe® Ultrasonic Level Transmitter ( Model: XP88-89 )

5
538
Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. ​​Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.

Application

FM approved for hazardous environments, the explosion proof ultrasonic level transmitter provides continuous level measurement up to 32.8' (10m) with a 4-20 mA signal output, and is configured via the integral push button display module. This non-contact liquid level sensor is ideally suited for corrosive, ultrapure, sticky or dirty liquids, and is widely selected for bulk storage, day tank, lift station and process tank level applications located in a classified area.

Features

Explosion proof level transmitter for use in hazardous areas

Offered in 2 measurement ranges from 26.2' (8m) to 32.8? (10m)

Configuration is simple via integral push button display module

Type 4 aluminum XP windowed enclosure with dual conduit ports

LCD display indicates level in inches, centimeters or percent of span

Narrow 3" beam width for applications with limited measurement space

Rugged PVDF transducer and process mounting plug for corrosive liquids

Automatic temperature compensation for accurate measurement

– See more at: http://www.flowline.com/echosafe.php#sthash.zncN2esz.dpuf

Application:
FM approved for hazardous environments, the explosion proof ultrasonic level transmitter provides continuous level measurement up to 32.8' (10m) with a 4-20 mA signal output, and is configured via the integral push button display module. This non-contact liquid level sensor is ideally suited for corrosive, ultrapure, sticky or dirty liquids, and is widely selected for bulk storage, day tank, lift station and process tank level applications located in a classified area.
Features:

Explosion proof level transmitter for use in hazardous areas

Offered in 2 measurement ranges from 26.2' (8m) to 32.8? (10m)

Configuration is simple via integral push button display module

Type 4 aluminum XP windowed enclosure with dual conduit ports

LCD display indicates level in inches, centimeters or percent of span

Narrow 3" beam width for applications with limited measurement space

Rugged PVDF transducer and process mounting plug for corrosive liquids

Automatic temperature compensation for accurate measurement

Specifications

Range: XP88: 8" to 26.2' (20cm to 8m)
XP89: 8" to 32.8' (20cm to 10m)
Accuracy: ± 0.2% of range
Resolution: 0.079" (2mm)
Dead band: 8" (20cm)
Beam width: 3" (7.6cm)
Configuration: Push button
Memory: Non-volatile
Display type: LCD, 6-digit
Display units: Inch, cm, percent, feet or meter
Supply voltage: 18-28 VDC (loop)
Loop resist.: 250 Ohms max @ 24 VDC
Signal output: 4-20 mA, two-wire
Signal invert: 4-20 mA or 20-4 mA
Signal fail-safe: 4 mA, 20mA, 21 mA, 22 mA
or hold last
Process temp.: F: -4° to 140°
C: -20° to 60°
Temp. comp.: Automatic
Ambient temp.: F: -4° to 140°
C: -20° to 60°
Pressure: MWP = 30 psi (2 bar)
Enclosure rating: Type 4
Encl. material: Aluminum
Window material: Glass
Conduit entrance: Dual, 1/2" NPT
Trans. material: PVDF
Process mount: 2" NPT
Mount gasket: Viton®
Classification: Explosion proof
Compliance: CE, RoHS
Approvals: FM: Class I, Div I
Groups A, B, C, D
Class II/III, Div I,
Groups E, F, G

– See more at: http://www.flowline.com/echosafe.php#sthash.zncN2esz.dpuf

Specifications:
Range:     XP88: 8" to 26.2' (20cm to 8m)
XP89: 8" to 32.8' (20cm to 10m)
Accuracy:     ± 0.2% of range
Resolution:     0.079" (2mm)
Dead band:     8" (20cm)
Beam width:     3" (7.6cm)
Configuration:     Push button
Memory:     Non-volatile
Display type:     LCD, 6-digit
Display units:     Inch, cm, percent, feet or meter
Supply voltage:     18-28 VDC (loop)
Loop resist.:     250 Ohms max @ 24 VDC
Signal output:     4-20 mA, two-wire
Signal invert:     4-20 mA or 20-4 mA
Signal fail-safe:     4 mA, 20mA, 21 mA, 22 mA
or hold last
Process temp.:     F: -4° to 140°
C: -20° to 60°
Temp. comp.:     Automatic
Ambient temp.:     F: -4° to 140°
C: -20° to 60°
Pressure:     MWP = 30 psi (2 bar)
Enclosure rating:     Type 4
Encl. material:     Aluminum
Window material:     Glass
Conduit entrance:     Dual, 1/2" NPT
Trans. material:     PVDF
Process mount:     2" NPT
Mount gasket:     Viton®
Classification:     Explosion proof
Compliance:     CE, RoHS
Approvals:     FM: Class I, Div I
Groups A, B, C, D
Class II/III, Div I,
Groups E, F, G

Resource & Download

Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | 086 9421303 | 02873000184 | Flowline-EchoSafe® Ultrasonic Level Transmitter ( Model: XP88-89 ).

Comments are closed.