Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.
The Guardian 6100 Plus is able to perform several dielectric tests in one unit including AC/DC Hipot, Insulation Resistance,Ground Bond, Open/Short Check and optional Leakage Current for compliance testing of IEC, UL, TUV, CSA, EN and other standards including IEC60601-1, UL2601-1, IEC950, UL544, UL60950. The time-saving TwinPort™ feature performs Hipot and Ground Bond simultaneously cutting time for these tests in half. The open / short check function (OSC) checks for an open connection or a DUT short during testing. Open connections may cause a bad DUT to test OK. Screening for shorts prevents damage to the equipment saving potential costs that may occur. These patented features are only available in safety products manufactured by Chroma.
The Guardian 6100 Plus Safety Analyzer’s leakage current scanners (A190308) can provide up to 20A input current capability for functional run testing as well as earth, enclosure, patient and line leakage current tests meeting IEC60601-1 compliance requirements.
- Plugs into the Guardian 6100 Plus for Hipot, Line Leakage Auto Scanning
- Five Different Kinds Human Body RC Network
- Four measurements mode : Normal, Reverse, Single Fault Normal, Single Fault Reverse
- Up to 20A Line Input Current Capability
- Build in A/D and Calibration Data Memory Easy to Install
- Multiple Display Mode Voltage-LC, Amp-LC, VA-LC
- Earth LC, Enclosure LC, Patient LC and Patient Auxiliary LC Test
Applications
Production and Compliance Testing of Medical Devices in Accordance with IEC, UL, CSA, EN and Other Standards such as IEC60601-1, UL2601-1, IEC950, UL544 and UL60950
- ITE / consumer electronic safety testing
- Transformer safety testing
- Generator/motor safety testing
- Component safety testing
- Non-electronic safety testing
- Appliance electrical safety testing
- Medical equipment safety testing
Specifications
Guardian 6100 Plus |
Mode |
AC / DC / IR / GB / LC |
Withstanding Voltage Test |
Output Voltage |
DC:0.05 ~ 6kV , AC : 0.05 ~ 5kV |
Load Regulation |
±(1% of reading +0.1% of range) |
Voltage Regulation |
2V |
Voltage Accuracy |
±(1% of reading +0.1% of range) |
Cutoff Current |
DC : 20mA , AC : 40mA |
Current Resolution |
0.1 μA DC |
Current Accuracy |
±(1% of reading +0.1% of range) |
Output Frequency |
50Hz / 60Hz |
Test Time |
0.3 ~ 999 sec , continue |
Ramp Time |
0.1 ~ 99.9 sec, Off |
Fall Time |
0.1 ~ 99.9 sec, Off |
Waveform |
Sine wave |
Insulation Resistance Test |
Output Voltage |
DC : 0.05 ~ 1kV |
Voltage Resolution |
2V |
Voltage Accuracy |
±(2% of reading +0.5% of range) |
IR Range |
1MΩ ~ 50GΩ |
Resistance Resolution |
0.1MΩ |
Resistance Accuracy |
5% typical |
Ground Bond Test |
Output Current |
AC : 1 ~ 30A (40A, 60A optional) |
Current Accuracy |
±(1% of reading +0.2% of range) |
GR Range |
10mΩ ~ 510mΩ |
Resistance Resolution |
0.1mΩ |
Resistance Accuracy |
± (1% of reading + 0.1% of full scale) |
Test Method |
4 wires |
Flashover Detection |
Setting Mode |
Programmable setting |
Detection Current |
AC : 20mA, DC : 10mA |
Secure Protection Function |
Panel Operation Lock |
Present password |
Interlock |
YES |
GO/NG Judgment Window |
Indication,Alarm |
GO: Short sound,Green LED; NG: Long sound, Red LED |
Data Hold |
Least tests data memories |
Memory Storage |
50 setups with up to 100 groups recall |
Interface |
9pin D-sub I/O control / RS232 / GPIB (Optional) |
General |
Operation Environment |
Temperature : 0°C ~ 40°C, Humidity : ± 80 % RH |
Power Consumption |
No load : < 100 W With rated load : 800 W |
Power Requirements |
90~132Vac or 198~264Vac, 47~66Hz |
Weight |
Approx. 20KG(19032) 25KG (19032-P) |
|
Ordering information
Guardian 6100 Plus: Electrical Safety Analyzer A190301: 8HV Scanning Box A190302: 5HV/3GC Scanner A190303: 3HV/5GC Scanner A190304: 8HV Scanner A190305: Line Leakage Current Scanner A190306: Hipot/Line Leakage/Probe Scanner (10A) A190307: L-N Scanner & Leakage Current Scanner A190308: Hipot/Line Leakage/Probe Scanner (20A) A190313: 500VA Isolation Transformer A190314: 1000VA Isolation Transformer
|
A190316: Dummy Load A190317: Bar Code Scanner A190321: GPIB Interface A190334: Ground Bond 40A A190337: Ground Bond 60A A190338: 19001 EST Software A190309: EMI FILTER Scanner A190342: EMI FILTER Test Box A190343: 19" Rack Mount Kit for Model 19032 A190344: HV Gun A190349: Universal Corded Product Adapter A190708: ARC Verification Fixture
|
Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó.
Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | 086 9421303 | 02873000184 | QuadTech Inc-Plus Medical Electrical Safety Analyzer (Model:Guardian 6100).
Comments are closed.