QuadTech Inc-Programmable AC Electronic Load (Model: 63800 Series)

0
540
Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. ​​Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.
  • Power Rating:1800W/3600W/4500W
  • Voltage Range: 50V – 350Vrms
  • Current Range: Up to 45Arms
  • Peak Current: Up to 135A
  • Frequency Range: 45 to 440Hz, DC
  • Crest Factor Range: 1.414 to 5.0
  • Parallel units for higher power or synchronize for three phase operation
  • Maximum paralleled power: 22.5KW single phase / 67.5KW three phase

The Chroma 63800 Loads can simulate load conditions under high crest factor and varying power factors with real time compensation even when the voltage waveform is distorted. This special feature provides real world simulation capability and prevents overstressing resulting in reliable and unbiased test results.

The 63800's state of the art design uses DSP technology to simulate non-linear rectified loads with its unique RLC operation mode. This mode improves stability by detecting the impedance of the UUT and dynamically adjusting the load's control bandwidth to ensure system stability.

Comprehensive measurements allow users to monitor the output performance of the UUT. Additionally, voltage & current signals can be routed to an oscilloscope through analog outputs. The instrument's GPIB/RS232 interface options provide remote control & monitor for system integration. Built-in digital outputs may also be used to control external relays for short circuit (crowbar) testing.

Chroma's 63800 Loads feature fan speed control ensuring low acoustic noise. The diagnosis/protection functions include selfdiagnosis routines and protection against overpower, over-current, over-voltage and overtemperature.

Complete AC & DC Load Simulations

Chroma's 63800 AC & DC Electronic Load is designed for both AC & DC Load Simulations. Illustrated below are the various load modes which are available:

AC & DC Load Modes

AC Load Simulation

The Model 63800 AC & DC Electronic Load provides two unique operating modes for AC load simulation; (1) Constant Load Modes and (2) Rectified AC Load Modes. Each are described below.

Constant Load Modes

The Constant Load Modes allow users to set the following operating modes: CC, CR and CP mode. The CC & CP modes in this category allow users to program PF or CF, or both. For CR mode the PF is always set to 1. The power factor range is limited based on crest factor programmed (Shown as Figure 1). If the programmed PF is positive then the current will lead the voltage waveform. When PF is set negative, the current will lag the voltage waveform. (See below)

Constant Load ModesCrest Factor vs. Power Factor Control Range
Figure 1: Crest Factor vs. Power Factor Control Range; CFI = I peak / I rms; PF = True power / Apparent power

Rectified AC Load Modes

The 63800 AC & DC Electronic Load provides unique capability to simulate non-linear rectified loads for a wide range of testing applications. There are three load modes available for rectified load simulations: RLC, CP and Inrush Current.

Figure 2 shows the typical model of a rectifier input. Under RLC mode, users can set the RLC values to 100% and simulate the behavior of the actual UUT. Figure 3 & 4 compares the voltage and loading waveforms between the actual RLC built circuit and the simulated rectified circuit by using Chroma's RLC load mode. The waveform obtained under CC mode with the same loading crest factor shown in Figure 5.

Rectified CircuitFigure 2: Typical Rectified Circuit

For inrush current simulation (See Figure 6), the 63800 provides an Inrush Current mode that allows the user to set different inrush current amplitude and voltage phase angle where the inrush current started.

voltage and loading waveforms voltage and loading waveforms CC Mode Inrush Current Simulation
Figure 3 Figure 4 Figure 5 Figure 6
DC Load Simulation

Chroma's 63800 DC load simulation includes four load modes: constant current, constant resistance, constant voltage and constant power as depicted below. CC, CR, CP mode can be used for regulated voltage power supply testing. For battery charger, CV mode may help to check its current regulation. Many inverter designs, although its input is DC, show an input current and will show rectified pattern. This unique load mode makes the Chroma 63800 load ideal for Fuel Cell, PV module/array and Battery testing.

Comprehensive Measurements

Chroma's 63800 Series AC & DC Electronic Loads include built-in 16-bits precision measurement circuits to measure the steady-state and transient responses for true RMS voltage, true RMS current, true power(P), apparent power(S), reactive power(Q), crest factor, power factor, THDv and peak repetitive current. In additional to these discrete measurements, two analog outputs, one for voltage and one for current, are provided as a convenient means of monitoring these signals via an external oscilloscope.

Timing Measurement

Timing parameters are critical to many products such as UPS's Breakers and Fuses. The 63800 AC & DC Load also includes a unique timing and measurement function to measure the trip time of fuses & circuit breakers or the transfer time for UPS's (Off-Line).

Timing ParametersFigure 7: Transfer time for Off-Line UPS

Automatic Bandwidth Adjustment (ABA)

When the UUT, such as one shown in Figure 8, has a higher output impedance, the current waveform will not be stable without ABA. In most cases, the loading current will be oscillating and spoil the test.

Fixed BandwidthFigure 8: Fixed Bandwidth

With ABAFigure 9: With ABA
Note 1: A test current will be programmed prior the actual loading defined by user for impedance detection.

Parallel / 3-Phase Control

The 63800 series provides parallel and 3-phase functions for high power and three phase applications. All the models within the 63800 series can be used together for both parallel and 3-phase functions as well as paralleled AC Load units in a 3-phase configuration, providing excellent flexibility and cost savings for the 63800 series AC load.

 Parallel connectionFigure 10: Parallel connection

 Parallel/3-Phase Y connectionFigure 11: Parallel/3-Phase Y connection

 Parallel/3-Phase Y connectionFigure 12: Parallel/3-Phase Delta connection

Auto Power Factor Correction

Setting the power factor is one of the major features to the 63800. The power factor is defined as:

Power Factor

Since PF is a function of real time voltage and current, traditional AC load designs assume the voltage waveform to be sinusoidal all the time, as seen Figure 13. This is not realistic because the voltage waveform may be distorted after the load is applied shown in Figure 14.

Voltage WaveformFigure 13

Voltage WaveformFigure 14

Resource & Download

Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | 086 9421303 | 02873000184 | QuadTech Inc-Programmable AC Electronic Load (Model: 63800 Series).