Key Facts
- Short measurement times
- Wide dynamic range
- High output power
- Wide power sweep range
- Balanced measurements
- Parallel measurements
- Innovative user interface
- Convenient and flexible analysis function
Features & Benefits
-
High performance for fast and reliable measurements
- Reflectometers with separate measurement and reference channels
- Parallel measurements on multiple ports
- Data processing and transfer simultaneously with measurement
- DC bias for active DUTs
-
Ergonomic user interface
- User-configurable display of results
- Manual operation support
- Fast switching between instrument setups
- Editor for trace mathematics
-
Advanced measurement functionality
- Independent channels
- Convenient marker and analysis functions
- Integrated PC with Windows XP
-
Highlights of the R&S®ZVB in production
- Integrated PC with Windows XP for automated procedures and data management
- Optimization of test and production sequences
- Mixer and harmonics measurements
Brief Description
Built using innovative hardware and software concepts, the vector network analyzers of the R&S®ZVB family set new standards: One generator can feed two test ports simultaneously. This makes parallel measurements possible, significantly increasing performance despite the complexity of the measurement task at hand.
Characteristics
The R&S®ZVB series of vector network analyzers covers the frequency ranges from 10 MHz to 14/20 GHz. It has been designed for universal measurements on passive and active components. The R&S®ZVB series greatly simplifies vector network analysis especially for multiport measurements and measurements on balanced devices. Featuring comprehensive measurement functions, excellent specifications, high measurement and data transfer speeds and remote-control capability, the analyzers of the R&S®ZVB series are an ideal choice for both development and production applications. The compact versions of the 14 GHz and 20 GHz two-port models leave ample room for test setups in the lab, featuring a height of only 24 cm and a depth of 42 cm.
- New multiport concept
- Instruments with two or four test ports – for multiport and balanced measurements
- Two internal sources (four-port models) – to provide RF and LO signals for mixer measurements by means of a single unit
- Capability to perform balanced measurements – to characterize balanced DUTs by their mixed mode S-parameters
- Optional automatic calibration units – to speed up calibration and avoid operator errors
- Outstanding specifications (best values chosen)
- 60001 points per trace
- Dynamic range better than 123 dB (typ. 130 dB)
- Power sweep range >50 dB (typ.)
- High speed
- Measurement time < 4.5 ms for 201 test points (frequency sweep)
- Switching time between channels < 1 ms
- Switching time between instrument setups < 10 ms
- Data transfer time < 0.7 ms (201 test points via RSIB)
- Simultaneous measurement of more than one DUT
- Modern user interface
- Intuitive Windows-based operation via mouse
- Operation by means of hardkeys and softkeys
- Large number of channels, traces and setups that can be loaded simultaneously
Specifications
Measurement time per point | CW mode, at 500 kHz IF bandwidth | < 4.5 μs |
Measurement time (including any data transfer time) |
201 measurement points, measurement bandwidth 500 kHz, display off, ALC off, at 5 GHz, narrow span |
< 4.5 ms |
Data transfer time | data transfer simultaneous with measurement | |
Dynamic range | at 10 Hz IF bandwidth | > 120 dB |
Inherent noise | < –110 dBm | |
Power sweep range1) | –40 dBm to +13 dBm | |
IF bandwidths | 1 Hz to 500 kHz | |
Number of measurement points per trace | 1 to 60 001 | |
Platform | ||
Number of test ports | 2 or 4 | |
Number of measurement and reference receivers | one measurement and one reference receiver per test port |
|
Number of integrated generators | one generator per test port pair | |
Calibration techniques | TOSM, UOSM, TRL/LRL, TOM, TRM, TNA, automatic calibration unit |
|
Operating system and internal PC | Windows XP | |
Operation | hardkeys/softkeys, keyboard and mouse, online help system, measurement and calibration wizard |
|
Number of traces, diagrams, independent channels, setups that can be simultaneously loaded into RAM | > 1002), traces can be assigned to diagrams as required |
1) Power level that can be electronically swept.
2) Number limited only by internal memory.