Shimadzu-UV-VIS Spectrophotometer (Model:UVmini-1240 )

2
613
Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. ​​Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.
Minimal Training – Easy to Use
The large liquid-crystal display (LCD) has been incorporated with easy to follow prompts, large fonts, and graphics to help reduce the time needed to get your results. The description on the instruments' soft keypad quickly guides you through specific programs.

Mighty Performance with Quantitative Methods

Everything from simple concentration measurements up to sophisticated quantitative calibration curves. Some of the standard functions include:

  • Factor method for input of simple constants
  • One point calibration curve with one standard sample and a point through the origin.
  • Multi-point calibration curve of the application requiring various standards. 1st, 2nd, and 3rd order polynomial filling for calibration come standard.
  • Two or three wavelength quantitative analysis for measuring turbid samples or for measuring the effects of another distinguishable component.

Maximum Wavelength Scanning

The UVmini comes standard with a Spectrum mode that allows for full spectral data acquisition over the wavelength range of 190nm to 1100nm. Upon completion of the spectral scan, the peaks and valleys can be marked within a few seconds. The standard peak pick function allows for clear and accurate detection of the most sensitive wavelengths.

Mega Data Archiving Capabilities

Methods, results and raw data can be saved on either the standalone instrument, optional dedicated IC Data cards, or within a directory of an IBM-Compatible PC with the help of the optional NEW UV DATA MANAGER software. This provides unlimited storage and expanded capabilities in archiving methods and management of essential results.

Multiple Print Utilities

The UVmini provides flexible print options with the use of either a thermal screen copy printer or a variety of different PC printers. The screen copy printer enables instant printing of tabulated data, as well as copied information directly from the screen. The PC printers can be utilized for the same functions and for finer print resolution of spectral data.

Mini Effort to Customize

With over 35 different types of attachments including multicell positioners, sippers, temperature control devices, the UVmini can provide all the tools necessary to fit your specific application. The IC program cards quickly expand the functionality of the instrument. By simply inserting the appropriate IC card into the slot on the front panel, dedicated applications such as DNA/Protein analysis can now be performed.

Hardware Specifications UVmini-1240

Item UVmini-1240
Spectrum bandwidth 5 nm
Wavelength range 190.0 to 1100.0 nm
Display wavelength 0.1 nm step
Selectable wavelength 0.1 nm step (1nm step in spectrum mode)
Wavelength accuracy ± 1.0 nm
Wavelength repeatability ± 0.3 nm
Scan speed Wavelength change: approximately 3800 nm/min
Scan: approximately 24 to 1400 nm/min
Light source change Selectable from following 3 types;
  – Auto change with wavelength
    Selectable wavelength 295 nm to 364 nm: 1 nm interval
    Recommended wavelength: 340 nm
  – Halogen lamp (WI) only
  – Deuterium (D2) lamp only
Stray light less than 0.05%
(220.0 nm NaI, 340.0 nm NaNO2 & UV39)
Measurement method Single beam measurement
Photometric range Absorbance: −0.3 to 3.0 Abs
Transmittance: 0.0 to 200%
Recording range Absorbance: −3.99 to 3.99 Abs
Transmittance: −399 to 399%
Photometric accuracy ± 0.005 Abs (at 1.0 Abs)
± 0.003 Abs (at 0.5 Abs)
Photometric repeatability ± 0.002 Abs (at 1.0 Abs)
Drift less than ± 0.001 Abs/h (after 2 hr warm-up)
Baseline flatness ± 0.010 Abs (after 1 hr warm-up, at 1100 to 200 nm)
Noise less than 0.002 Abs, Peak to Peak
less than 0.0005 Abs, RMS
Light source Auto correction with the computer memory
20W Halogen lamp (long-life 2000 hours)
Deuterium lamp (socket type)
Auto adjustment for maximum sensitivity
Monochromator Incorporates aberration-correcting concave blazed holographic grating
Detector Silicon photodiode
Sample compartment Interior dimensions W110.0 × D230.0 × H105.0 mm
(partial depth: 155.0 mm)
2 screw port for option accessory installation
Display 6 inch LCD (320 X 240 dot) with CFD lighting with contrast adjustment
Power supply 100 to 120 V 50/60 Hz 160 VA
220 to 240 V 50/60 Hz 160 VA
Dimensions W416 X D379 X H274 mm
Weight 11 kg
Ambient temperature 15 to 35°C
Ambient humidity 45 to 80%, less than 70% if over 30°C
Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | 086 9421303 | 02873000184 | Shimadzu-UV-VIS Spectrophotometer (Model:UVmini-1240 ).

Comments are closed.